By using an ats or changeover switch allows you to switch between solar and grid. 7000 series medium voltage transfer switches.
Datakom Dkg 171 Generator Mains Automatic Transfer Switch Control Panel Ats
Ats contactor diagram. Typical service entrance open transition ats. Starting with basics in automatic transfer switch equipment the switchs intelligence system initiates the transfer when normal power fails or falls below a preset voltage. Breaker contactor or motorised switch socomec diagram. Eatons contactor type automatic transfer switches ats are designed to quickly and reliably transition critical loads between preferred and alternategenerator power sources. The open and delayed transition contactor based automatic transfer switch ats provides fully functioning transfer in applications where a momentary loss of power is acceptable during transfer and retransfers between normal and emergency power. Load bank series numbers explained.
In our step by step electrical wiring installation tutorials series we will show how to wire and connect single phase and three phase automatic and manual changeover and transfer switches to the home distribution board to use the backup power supply such us batteries power with ups and inverters or generator power in case of emergency breakdown and power outage. How you can utilize contactors as automatic transfer switch between grid and solar more information below. 7000 series transfer switch. An automatic transfer switch ats for a single phase power generator has been designed to enable the automatic operation and transfer of power supply between a public utility supply and a power. Service entrance contactor based transfer switch figure 3. Testing diesel gen sets to iso8528.
Four main panels comprise the contactor based ats design and are shown in figure 3. Technical information 3 standard diagrams transfer between 2 sources 1 bus bar comut 041 a load g s1 g s2 p1 p2 standard solution. The eaton contactor based ats is designed with easy installation and simplified maintenance in mind. Ideal for use in nfpa 70 emergency legally required optional standby and critical operations systems that demand reliable performance. A simple circuit diagram either of the two start buttons will close the contactor either of the stop buttons will open the contactor. Monitoring engine start signals.
Asco sigma wireless gateway simplifies load bank. Cat transfer switches are designed for a variety of standby power applications. Note that one one of the contactor acts as a switch for the start button. Series 175 surge protective device. Motorised switch cl ncl g q1 q2 ats automatic transfer switch protection arent shown on the following schemes summary. They provide flexibility reliability and value in a compact package.
If the emergency power source is a standby generator the transfer switch initiates generator starting and transfers to the emergency power source when sufficient generator voltage is available.