A stair case wiring can be used only for human comfort. To study and perform the godown wiring.
Lc 6965 Connection Diagram Of Godown Wiring
Godown wiring system. Here one lamp is controlled by two switches from two different positions. The following will assist you with godown wiring. Installing a motion detector or occupancy sensor to turn the lights on and off. In the second light switch wiring only one light on at a time and others are switch off. Installing a switch controlled relay system. It was the best choice to save electricity and energy consumption where only one load ie.
This type of wiring is used in bed rooms to switch onoff the lamp from two sources at the bed side and at switchboard. Etc where the light is only required for passage or it requires only at one position at a time. Although this is a method of switch wiring that works quite well it does have one drawback because the lighting will work for only one occupant in one area. Name nos rating switch1 way 1 230v50hz6a switch2 way 3 230v50hz6a lamp 4 40 watt fuse 1 6a lamp holder 3 230v50hz mcb 1 230v50hz wires. Two way switch 5a 230 v 2 nos. Stair case wiring or godown wiring or warehouse wiring is a term used to denote where a single light is controlled from various places.
Godown wiring circuit is needed in tunnel like structures warehouses long passages big godowns having lots of rooms and different portions. One light two switches wiring. Staircase wiring is a common multi way switching or two way light switching connection. If any person enters the godown or in the tunnel and at first he presses the switch s1 then light x1 turn on now he goes to next and press switch s2 then the light x2 will turn on only and light x1 automatic switched off. This type wiring is used in big godowns long passages warehouses and tunnel like structures having many rooms or portions. As its name implies godown wiring it is commonly used for light switching in godowns tunnel like structures long passages.
The godown wiring method is popular for warehouses where there is one entrance and the lighting should be on only in the occupied area. The connection of switches with the lamp is shown below. Godown wiring uses to operate lampsloads in a sequential manner where only one load operates at a time. Three godown wiring methods. That is to operate the load from separate positions such as above or below the staircase from inside or outside of a room or as a two way bed switch etc. Not only a light we can also adopt this wiring technique for some other electrical devices.
Light bulb can be operate at a time. As its name implies godown wiring it is used in godowns tunnel like structures long passages. The godown system may be wired using mechanical 2 pole switches. Godown wiring uses to operate lamps loads in a sequential manner where only one load operates at a time.